Permeation breakthrough times according to EN374-3:2003

Glove Style Breakthrough Time Protection Index CAS Number Notified Body EN Standard
 
Sol-Knit® 39124 >480 6 121-44-8 Centexbel 374-3:2003
 
Sol-Knit® 39122 >480 6 121-44-8 Centexbel 374-3:2003
 
VersaTouch® 92-471 92-481 92-465 92471 66 3 121-44-8 Centexbel 374-3:2003
 
Barrier® 02100 > 480 6 121-44-8 Centexbel 374-3:2003
 
Bi-Colour™ 87900 5 0 121-44-8 Centexbel 374-3:2003
 
Extra™ 87950 13 1 121-44-8 Centexbel 374-3:2003
 
Extra™ 87955 13 1 121-44-8 Centexbel 374-3:2003
 
Neotop® 29500 23 1 121-44-8 Centexbel 374-3:2003
 
NeoTouch® 25101 < 5 0 121-44-8 Centexbel 374-3:2003
 
NeoTouch® 25201 < 5 0 121-44-8 Centexbel 374-3:2003
 
PVA® 15554 > 480 6 121-44-8 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08352 < 5 0 121-44-8 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08354 < 5 0 121-44-8 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37675 > 480 6 121-44-8 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37676 > 480 6 121-44-8 Centexbel 374-3:2003
 
Solvex® 37-900 37900 > 480 6 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 92-665 92-670 92670 66 3 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92500 155 4 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92600 155 4 121-44-8 Centexbel 374-3:2003
 
Virtex™ 79700 100 3 121-44-8 Centexbel 374-3:2003
 
VersaTouch® 92-471 92-481 92-465 92481 66 3 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 92-665 92-670 92665 66 3 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92605 155 4 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 93-300 93-700 93300 155 4 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 93-300 93-700 93700 155 4 121-44-8 Centexbel 374-3:2003
 
VersaTouch® 92-471 92-481 92-465 92465 66 3 121-44-8 Centexbel 374-3:2003
 
TouchNTuff® 93-250 93250 155 4 121-44-8 Centexbel 374-3:2003
Permeation breaktrough times according to EN374-3:2003 (minutes)
0 1 2 3 4 5 6
< 10 10-30 30-60 60-120 120-240 240-480 > 480
Not recommended Splash protection Medium protection High protection
Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability.