Permeation breakthrough times according to EN374-3:2003

Glove Style Breakthrough Time Protection Index CAS Number Notified Body EN Standard
 
Barrier® 02100 > 480 6 7664-93-9 Centexbel 374-3:2003
 
Solvex® 37-900 37900 116 3 7664-93-9 Centexbel 374-3:2003
 
AccuTech® 91250 62 3 7664-93-9 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08352 302 5 7664-93-9 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08354 302 5 7664-93-9 Centexbel 374-3:2003
 
AlphaTec® AquaDri® 58-330 58-335 58330 42 2 7664-93-9 Centexbel 374-3:2003
 
AlphaTec® AquaDri® 58-330 58-335 58335 48 2 7664-93-9 Centexbel 374-3:2003
 
VersaTouch 37-510 & 37-646 37510 33 2 7664-93-9 Centexbel 374-3:2003
 
VersaTouch 37-510 & 37-646 37646 33 2 7664-93-9 Centexbel 374-3:2003
Permeation breaktrough times according to EN374-3:2003 (minutes)
0 1 2 3 4 5 6
< 10 10-30 30-60 60-120 120-240 240-480 > 480
Not recommended Splash protection Medium protection High protection
Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability.