Permeation breakthrough times according to EN374-3:2003

Glove Style Breakthrough Time Protection Index CAS Number Notified Body EN Standard
 
Barrier® 02100 > 480 6 7664-39-3 Centexbel 374-3:2003
 
Neotop® 29500 > 480 6 7664-39-3 Centexbel 374-3:2003
 
Profil™ Plus 87850 248 5 7664-39-3 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08352 > 480 6 7664-39-3 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08354 > 480 6 7664-39-3 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37675 179 4 7664-39-3 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37676 179 4 7664-39-3 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92600 < 5 0 7664-39-3 Centexbel 374-3:2003
 
AlphaTec® 58-530 58-535 58530W 48 2 7664-39-3 Force Technology 374-3:2003
 
Bi-Colour™ 87900 > 480 6 7664-39-3 Force Technology 374-3:2003
 
Duzmor® Plus 87600 > 480 6 7664-39-3 Centexbel 374-3:2003
 
proFood® Reusable Latex 87305 > 480 6 7664-39-3 Centexbel 374-3:2003
 
TouchNTuff® DermaShield® 73-701 73701 405 5 7664-39-3 Force Technology 374-3:2003
 
DermaShield® 73711 405 5 7664-39-3 Force Technology 374-3:2003
 
DermaShield® 73721 405 5 7664-39-3 Force Technology 374-3:2003
 
NeoTouch® 25101 29 1 7664-39-3 Force Technology 374-3:2003
 
NeoTouch® 25201 29 1 7664-39-3 Force Technology 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92605 < 5 0 7664-39-3 Centexbel 374-3:2003
 
Virtex™ 79700 9 0 7664-39-3 Force Technology 374-3:2003
 
AlphaTec® 58-530 58-535 58530B 48 2 7664-39-3 Force Technology 374-3:2003
 
TouchNTuff® 93-300 93-700 93300 <5 0 7664-39-3 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92500 < 5 0 7664-39-3 Centexbel 374-3:2003
 
TouchNTuff® 93-300 93-700 93700 <5 0 7664-39-3 Centexbel 374-3:2003
 
AlphaTec® 58-530 58-535 58535B 48 2 7664-39-3 Force Technology 374-3:2003
 
AlphaTec® 58-530 58-535 58535W 48 2 7664-39-3 Force Technology 374-3:2003
 
TouchNTuff® 93-250 93250 < 5 0 7664-39-3 Centexbel 374-3:2003
Permeation breaktrough times according to EN374-3:2003 (minutes)
0 1 2 3 4 5 6
< 10 10-30 30-60 60-120 120-240 240-480 > 480
Not recommended Splash protection Medium protection High protection
Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability.