Permeation breakthrough times according to EN374-3:2003

Glove Style Breakthrough Time Protection Index CAS Number Notified Body EN Standard
 
Barrier® 02100 > 480 6 75-15-0 Centexbel 374-3:2003
 
Bi-Colour™ 87900 < 5 0 75-15-0 Centexbel 374-3:2003
 
ChemTek™ 38514 < 5 0 75-15-0 Centexbel 374-3:2003
 
ChemTek™ 38520 < 5 0 75-15-0 Centexbel 374-3:2003
 
ChemTek™ 38628 > 480 6 75-15-0 Centexbel 374-3:2003
 
Duzmor® Plus 87600 < 5 0 75-15-0 Centexbel 374-3:2003
 
Extra™ 87950 < 5 0 75-15-0 Centexbel 374-3:2003
 
Extra™ 87955 < 5 0 75-15-0 Centexbel 374-3:2003
 
Neotop® 29500 < 5 0 75-15-0 Centexbel 374-3:2003
 
Polar Grip® 23700 < 5 0 75-15-0 Centexbel 374-3:2003
 
Profil™ Plus 87850 < 5 0 75-15-0 Centexbel 374-3:2003
 
PVA® 15554 > 480 6 75-15-0 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08352 < 5 0 75-15-0 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08354 < 5 0 75-15-0 Centexbel 374-3:2003
 
Snorkel® 04414 < 5 0 75-15-0 Centexbel 374-3:2003
 
Sol-Knit® 39122 < 5 0 75-15-0 Centexbel 374-3:2003
 
Sol-Knit® 39124 < 5 0 75-15-0 Centexbel 374-3:2003
 
Solvex® 37-185 37-186 37-655 37185 < 5 0 75-15-0 Centexbel 374-3:2003
 
Solvex® 37-185 37-186 37-655 37655 9 0 75-15-0 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37675 12 1 75-15-0 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37676 12 1 75-15-0 Centexbel 374-3:2003
 
Solvex® 37-900 37900 12 1 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92600 < 5 0 75-15-0 Centexbel 374-3:2003
 
Universal™ Plus 87650 < 5 0 75-15-0 Centexbel 374-3:2003
 
Universal™ Plus 87665 < 5 0 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92605 < 5 0 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 93-300 93-700 93300 <5 0 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 93-300 93-700 93700 <5 0 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 92-500 92-600 92-605 92500 < 5 0 75-15-0 Centexbel 374-3:2003
 
proFood® Reusable Latex 87305 < 5 0 75-15-0 Centexbel 374-3:2003
 
proFood® Reusable Latex 87315 < 5 0 75-15-0 Centexbel 374-3:2003
 
TouchNTuff® 93-250 93250 < 5 0 75-15-0 Centexbel 374-3:2003
Permeation breaktrough times according to EN374-3:2003 (minutes)
0 1 2 3 4 5 6
< 10 10-30 30-60 60-120 120-240 240-480 > 480
Not recommended Splash protection Medium protection High protection
Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability.