Permeation breakthrough times according to EN374-3:2003

Glove Style Breakthrough Time Protection Index CAS Number Notified Body EN Standard
 
AlphaTec® 58-530 58-535 58530B 5 0 75-05-8 Centexbel 374-3:2003
 
AlphaTec® 58-530 58-535 58535B 5 0 75-05-8 Centexbel 374-3:2003
 
Barrier® 02100 > 480 6 75-05-8 Centexbel 374-3:2003
 
Bi-Colour™ 87900 14 1 75-05-8 Centexbel 374-3:2003
 
ChemTek™ 38514 > 480 6 75-05-8 Centexbel 374-3:2003
 
ChemTek™ 38520 > 480 6 75-05-8 Centexbel 374-3:2003
 
ChemTek™ 38628 > 480 6 75-05-8 Centexbel 374-3:2003
 
TouchNTuff® DermaShield® 73-701 73701 8 0 75-05-8 Centexbel 374-3:2003
 
Duzmor® Plus 87600 8 0 75-05-8 Centexbel 374-3:2003
 
Neotop® 29500 21 1 75-05-8 Centexbel 374-3:2003
 
NeoTouch® 25101 < 5 0 75-05-8 Centexbel 374-3:2003
 
NeoTouch® 25201 < 5 0 75-05-8 Centexbel 374-3:2003
 
Nitrilite® 93311 < 5 0 75-05-8 Centexbel 374-3:2003
 
Nitrilite® 93401 < 5 0 75-05-8 Centexbel 374-3:2003
 
Polar Grip® 23700 9 0 75-05-8 Centexbel 374-3:2003
 
Profil™ Plus 87850 9 0 75-05-8 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08352 28 1 75-05-8 Centexbel 374-3:2003
 
Scorpio® 08-352 08-354 08354 28 1 75-05-8 Centexbel 374-3:2003
 
Sol-Knit® 39122 3 0 75-05-8 Centexbel 374-3:2003
 
Sol-Knit® 39124 3 0 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-185 37-186 37-655 37185 20 1 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-185 37-186 37-655 37655 10 0 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37675 5 0 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37676 5 0 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-675 37-676 37-695 37695 5 0 75-05-8 Centexbel 374-3:2003
 
Solvex® 37-900 37900 14 1 75-05-8 Centexbel 374-3:2003
 
Scorpio® 19-024 19-026 19026 7 0 75-05-8 Centexbel 374-3:2003
 
Universal™ Plus 87650 5 0 75-05-8 Centexbel 374-3:2003
 
Universal™ Plus 87665 5 0 75-05-8 Centexbel 374-3:2003
 
Virtex™ 79700 < 5 0 75-05-8 Centexbel 374-3:2003
 
AlphaTec® 58-530 58-535 58530W 5 0 75-05-8 Centexbel 374-3:2003
 
Scorpio® 09-022 09-430 09-922 09-924 09-928 09022 45 2 75-05-8 Centexbel 374-3:2003
 
proFood® Reusable Latex 87315 5 0 75-05-8 Centexbel 374-3:2003
 
AlphaTec® 58-530 58-535 58535W 5 0 75-05-8 Centexbel 374-3:2003
 
DermaShield® 73711 8 0 75-05-8 Centexbel 374-3:2003
 
DermaShield® 73721 8 0 75-05-8 Centexbel 374-3:2003
 
Scorpio® 09-022 09-430 09-922 09-924 09-928 09430 29 1 75-05-8 Centexbel 374-3:2003
 
Scorpio® 09-022 09-430 09-922 09-924 09-928 09922 29 1 75-05-8 Centexbel 374-3:2003
 
Scorpio® 09-022 09-430 09-922 09-924 09-928 09924 29 1 75-05-8 Centexbel 374-3:2003
 
Scorpio® 09-022 09-430 09-922 09-924 09-928 09928 29 1 75-05-8 Centexbel 374-3:2003
 
PVA® 15554 94 3 75-05-8 Centexbel 374-3:2003
 
Scorpio® 19-024 19-026 19024 7 0 75-05-8 Centexbel 374-3:2003
 
proFood® Reusable Latex 87305 8 0 75-05-8 Centexbel 374-3:2003
 
Emperor™ Mediumweight ME101 ME104 ME107 A005 > 480 6 75-05-8 Satra 374-3:2003
 
Emperor™ Mediumweight ME101 ME104 ME107 A008 > 480 6 75-05-8 Satra 374-3:2003
 
ChemTek™ 38-612 38612 > 480 6 75-05-8 Centexbel 374-3:2003
 
Emperor™ Heavyweight ME105 ME108 ME111 A006 > 480 6 75-05-8 Satra 374-3:2003
 
Emperor™ Heavyweight ME105 ME108 ME111 A009 > 480 6 75-05-8 Satra 374-3:2003
 
Emperor™ Heavyweight ME105 ME108 ME111 A300 > 480 6 75-05-8 Satra 374-3:2003
Permeation breaktrough times according to EN374-3:2003 (minutes)
0 1 2 3 4 5 6
< 10 10-30 30-60 60-120 120-240 240-480 > 480
Not recommended Splash protection Medium protection High protection
Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability.